PRODUCTS
- Autoclaves
- Baths & Circulators
- Chiller (Recirculating Cooler)
- Desiccators
- Environmental Chambers
- Temperature & Humidity Chamber Basic type (TH3-E)
- Temperature & Humidity Chamber Tabletop type (TH3-PE)
- Temperature & Humidity Chamber Tabletop type (TH3-ME)
- Temperature & Humidity Chamber Tabletop type (TH3-KE)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Fume Hoods
- Heating & Cooling Block
- Hotplate Stirrers & Stirrer
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate (Digital type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Heating Block (for Round Flask and Vial)
- Incubators
- Incubators (General, Air-jacket)
- Incubators (Film Heater, Economy)
- Incubators (Multi type Forced Convention)
- Low Temperature Incubators (Forced Convection)
- Low Temp. Incubators (Air-jacketed)
- Low Temperature Incubator (Personal)
- Low Temperature Incubator (Multi type, Forced Convention)
- Incubated Shakers (Tabletop)
- Incubated Shakers (Floor)
- Incubated Shaker (Multi-Stackable)
- Incubated Shaker (Stackable)
- Incubator (Mini type, Forced Convention)
- Industrial Test Equipment
- Forced Convection Ovens (Large-General)
- Forced Convection Ovens (Program, OF3-P)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G Type)
- Chiller (Recirculating Coolers) (General)
- Chiller (Recirculating Coolers) (Low Temp. General)
- Chiller (Recirculating Coolers) (High Temp. Precision)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Mixers
- Vortex Mixer
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Shaker (Compact)
- Microplate Shaker
- Rocking Shaker
- Waving Shaker
- Heating Shaker
- Ovens
- Vacuum Ovens
- Vacuum Ovens, OV4-S
- Forced Convection Ovens (Standard, OF4-S)
- Forced Convection Ovens (Advanced, OF4-V)
- Forced Convection Ovens (Program, OF4-P)
- Forced Convection Ovens (Program, OF3-P)
- Forced Convection Ovens (Large-General)
- Forced Convection Oven (Multi type, OF-02G-4C)
- Natural Convection Ovens (General, ON)
- Natural Convection Ovens (Economy)
- Muffle Furnace
- Pumps
- Refrigerators & Freezers
- Rotator
- Special Purpose Chamber
- Shaker
- Storage
- Fire Safety Storage Cabinet (Type 90)
- Fire Safety Storage Cabinet (Type 30)
- Acid / Corrosive Cabinets
- Molded Acid Corrosive Cabinet
- Multipurpose Cabinet (Window Type)
- Gas Cylinder Cabinets
- Laboratory Refrigerators
- Filtering Storage Cabinets
- Filtering Storage Refrigerator
- Laboratory Freezers
- Vacuum Desiccators (Cubic)
- Vacuum Desiccators (Round)
- Vacuum Desiccators (Cylindrical)
- Desiccators (Cubic Models)
- Temperature Chambers
- Heating & Cooling Chamber Tabletop type (TC3-ME)
- Heating & Cooling Chamber Tabletop type (TC3-KE)
- Forced Convection Ovens (Large- Programmable)
- Forced Convection Ovens (Large-General)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G)
- Plastic ware & Others
- Safety Waste Disposal System
- Handle Beaker (Transparent / Translucent)
- Wash Bottle
- Power Supply for Electrophoresis System
- Ultrasonic Cleaners
- Electrophoresis Systems
- Magnetic Drives
- Disposable Beaker
- Plastic Beakers
- Tubing Connectors
- Carboys
- Flask Supports
- On-Ice Rack
- Tube Rack
- Storage Boxes
- Cryo Boxes
- Clamp Holders
- Software
Environmental Chambers
- HOME
- > PRODUCTS
- > Environmental Chambers
- Autoclaves
- Baths & Circulators
- Chiller (Recirculating Cooler)
- Desiccators
- Environmental Chambers
- Temperature & Humidity Chamber Basic type (TH3-E)
- Temperature & Humidity Chamber Tabletop type (TH3-PE)
- Temperature & Humidity Chamber Tabletop type (TH3-ME)
- Temperature & Humidity Chamber Tabletop type (TH3-KE)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Fume Hoods
- Heating & Cooling Block
- Hotplate Stirrers & Stirrer
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate (Digital type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Heating Block (for Round Flask and Vial)
- Incubators
- Incubators (General, Air-jacket)
- Incubators (Film Heater, Economy)
- Incubators (Multi type Forced Convention)
- Low Temperature Incubators (Forced Convection)
- Low Temp. Incubators (Air-jacketed)
- Low Temperature Incubator (Personal)
- Low Temperature Incubator (Multi type, Forced Convention)
- Incubated Shakers (Tabletop)
- Incubated Shakers (Floor)
- Incubated Shaker (Multi-Stackable)
- Incubated Shaker (Stackable)
- Incubator (Mini type, Forced Convention)
- Industrial Test Equipment
- Forced Convection Ovens (Large-General)
- Forced Convection Ovens (Program, OF3-P)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G Type)
- Chiller (Recirculating Coolers) (General)
- Chiller (Recirculating Coolers) (Low Temp. General)
- Chiller (Recirculating Coolers) (High Temp. Precision)
- Temperature & Humidity Chamber (Low Temp. TH-G)
- Temperature & Humidity Chambers Low Temperature (TH-KH)
- Temperature & Humidity Chamber (General TH-TG)
- Pharmaceutical Stability Test Chamber
- Plant Growth Chambers
- Mixers
- Vortex Mixer
- Magnetic Stirrers (Analog)
- Magnetic Stirrers (Digital)
- Magnetic Stirrers (Multi Position)
- Hotplate & Magnetic Stirrers (Analog type)
- Hotplate & Magnetic Stirrers (Digital type)
- Hotplate & Magnetic Stirrers (Multi type)
- Overhead Stirrers (Prestige touch)
- Overhead Stirrers (High Performance)
- Overhead Stirrers (Easy Control)
- Shaker (Compact)
- Microplate Shaker
- Rocking Shaker
- Waving Shaker
- Heating Shaker
- Ovens
- Vacuum Ovens
- Vacuum Ovens, OV4-S
- Forced Convection Ovens (Standard, OF4-S)
- Forced Convection Ovens (Advanced, OF4-V)
- Forced Convection Ovens (Program, OF4-P)
- Forced Convection Ovens (Program, OF3-P)
- Forced Convection Ovens (Large-General)
- Forced Convection Oven (Multi type, OF-02G-4C)
- Natural Convection Ovens (General, ON)
- Natural Convection Ovens (Economy)
- Muffle Furnace
- Pumps
- Refrigerators & Freezers
- Rotator
- Special Purpose Chamber
- Shaker
- Storage
- Fire Safety Storage Cabinet (Type 90)
- Fire Safety Storage Cabinet (Type 30)
- Acid / Corrosive Cabinets
- Molded Acid Corrosive Cabinet
- Multipurpose Cabinet (Window Type)
- Gas Cylinder Cabinets
- Laboratory Refrigerators
- Filtering Storage Cabinets
- Filtering Storage Refrigerator
- Laboratory Freezers
- Vacuum Desiccators (Cubic)
- Vacuum Desiccators (Round)
- Vacuum Desiccators (Cylindrical)
- Desiccators (Cubic Models)
- Temperature Chambers
- Heating & Cooling Chamber Tabletop type (TC3-ME)
- Heating & Cooling Chamber Tabletop type (TC3-KE)
- Forced Convection Ovens (Large- Programmable)
- Forced Convection Ovens (Large-General)
- Heating Chambers (LBV)
- Heating Chambers (LTV)
- Heating & Cooling Chambers (KBD)
- Heating & Cooling Chambers (KMV)
- Heating & Cooling Chambers (JMV)
- Heating & Cooling Chambers (PBV)
- Heating & Cooling Chambers (PMV)
- Heating & Cooling Chambers (LCH)
- Heating & Cooling Chambers (LCH-G)
- Plastic ware & Others
- Safety Waste Disposal System
- Handle Beaker (Transparent / Translucent)
- Wash Bottle
- Power Supply for Electrophoresis System
- Ultrasonic Cleaners
- Electrophoresis Systems
- Magnetic Drives
- Disposable Beaker
- Plastic Beakers
- Tubing Connectors
- Carboys
- Flask Supports
- On-Ice Rack
- Tube Rack
- Storage Boxes
- Cryo Boxes
- Clamp Holders
- Software
Temperature & Humidity Chamber (General TH-TG)
Economy environmental test chamber.
Stability test in accordance with ICH guidelines Q1A (R2)
Model Name : TH-TG-180/300/408/800/1000/1500
Control range
- Temperature range from -5 to 100°C Humidity range from 10 to 95% RH
- Temperature range from -5 to 100°C Humidity range from 20 to 95% RH
Performance
- Microprocessor PID control / Temperature calibration / Automatic tuning.
- Advanced performance of low and high temperature and humidity control, achieved by adapting the humidification tank exterior to the chamber, added benefit for long term test.
- Water recycling system reduce water consumption for longer operation.
- Air-tight door closure with perfect sealed packing.
- Heat-resistant silicone packing completely blocks high heat leakage from the inner chamber.
- Two-point door latch also enhances tightness to door closure. - Energy efficiency is achieved by optimization of the insulation system.
- Even if the unit is operating at max. temperature, the surface of the unit doesn’t allow high temperatures of over 60℃.
Safety
- Built in door lock with a key.
- Automatic shut off after overheat alarm.
- Low and empty water level alarm.
- Power supply leakage breaker.
- Over current protection.
- Open door alarm.
LCD controller
-
Computer panel
-
Viewing window
-
Portable water container
Convenience
- Spacious chamber volume with a maximum capacity of 1500L.
- Various volume sizes, available to suit any users’ need. - Corrosion resistance stainless steel chamber and electric polished humidification tank.
- Maintenance of water supply are easily performed with a front water tank.
- Portable water container makes supplying water convenient. - Water supply during operation is also available for long term test purposes.
- Direct water system provides user great convenience when performing long-term tests. (optional)
- Clear observation of samples.
- Tempered glass door with built in heating wire.
- Energy efficient, long life span LED lighting.
- Wider view, inner glass door is available for monitoring of samples. (optional) - Cable port for introduction of external probes or wires.
- 50mm diameter cable port comes standard on the left side of the unit.
- Additional 50mm or 80mm diameter cable ports, custom ordered. (optional) - Casters for easy mobility during installation or relocation.
- User friendly LCD controller.
- Colorful interactive touch type LCD controller.
- Set point temperature and present temperature are clearly shown together on display.
- Sufficient programmable control support.
- Operating progress can be shown in graph mode for better data understanding.
- Automatic start/stop can be programmed for unattended operations.
- Display indicates abnormal temperature changes or power failures.
- Selective bilingual language support.
(Korean / English or English / Chinese, selectable only when placing an order)
- Temperature and other operating parameters can be recorded using a six channel digital recorder.(optional) - Computer interface.
- RS-485 communication port (optional) enables connection up to maximum 32 units. Simultaneous monitoring and operating of multiple units is an available feature.
- Program patterns are simple to set with the use of our software.
- Easy to check status of real-time operations. Graph data supports easy understanding.
- Storage and documentation of programs.
- Data with saving capabilities in excel and text format.
- Storage of program information, backup of value settings, recovery, and temperature values.
- RS-232 communication port as standard offer.
Description | No |
---|---|
Programmable pattern capacity | 100 |
Pattern repeat time | 999 |
Part repeat time | 255 |
Max. segments per a pattern | 100 |
Available max. segments* | 2000 |
Programmable process time per a segment | 0 to 99 hr. 59 min. |
* It is possible to set 100 segments per pattern, but the maximum number of segments is not 10,000 (100 pattern x 100 segment) but 2,000.
Model | TH-TG-180 | TH-TG-300 | TH-TG-408 | TH-TG-800 | TH-TG-1000 | TH-TG-1500 | ||
---|---|---|---|---|---|---|---|---|
Chamber volume (L / cu ft) |
180 / 6.4 |
314 / 11.1 |
419 / 14.8 |
770 / 27.2 |
997 / 35.2 |
1540 / 54.4 |
||
Controller |
PID control (LCD Type) |
|||||||
Temperature 1) |
Range |
without humidity (℃/℉) |
-5 to 100 / 23 to 212 |
|||||
with humidity (℃/℉) |
10 to 90 / 50 to 194 |
20 to 90 / 68 to 194 |
||||||
Fluctuation1) (±℃/℉) at 40℃/60%RH |
0.3 / 0.55 |
|||||||
Variation1) (±℃/℉) at 40℃/60%RH |
0.5 / 0.9 |
|||||||
Time |
Heating |
50min (-5℃ → 100℃) |
55min (-5℃ → 100℃) |
|||||
Cooling |
120min (100℃ → -5℃) |
145min (100℃ → -5℃) |
||||||
Humidity |
Range (%RH) |
10 to 95 ※ See feature page for more detailed humidity range check. |
25 to 95 ※ See feature page for more detailed humidity range check. |
|||||
Fluctuation2) (±%RH) at 60%RH/40℃ |
2 |
|||||||
Variation2) (±%RH) at 60%RH/40℃ |
3 |
|||||||
Refrigeration |
System |
Air - cooled |
||||||
Refrigerant |
R- 507A |
|||||||
Water tank |
Capacity (L / cu ft) |
15 / 0.53 |
30 / 1.1 |
|||||
Water quality |
pH6.2 ~ 7.2, Electrical conductivity 20㎲ / cm to below |
|||||||
No. of wire shelves (standard / max.) |
2 / 7 |
2 / 8 |
2 / 8 |
2 / 17 |
2 / 17 |
2 / 17 |
||
Distance of between shelves (mm / inch) |
60 /2.4 |
60 /2.4 |
60 /2.4 |
60 /2.4 |
60 /2.4 |
60 /2.4 |
||
Max. load per shelf (kg / lbs) |
20 / 44.1 |
25 / 55.1 |
25 / 55.1 |
40 / 88.2 |
40 / 88.2 |
40 / 88.2 |
||
Permitted total load (kg / lbs) |
50 / 110.2 |
65 / 143.3 |
65 / 143.3 |
100 / 220.5 |
100 / 220.5 |
100 / 220.5 |
||
Dimension (W×D×H) |
Viewing window (mm / inch) |
200×330 / 7.9×13 |
||||||
Interior (mm / inch) |
500×600×600/ 19.7×23.6×23.6 |
748×600×700/ 29.4×23.6×27.6 |
748×800×700/ 29.4×31.5×27.6 |
748×920×1120/ 29.4×36.2×44.1 |
748×1190×1120/ 29.4×46.9×44.1 |
1100×1000×1400/ 43.3×39.4×55.1 |
||
Exterior (mm / inch) |
952×907×1503/ 37.5×35.7×59.2 |
1201×907×1525/ 47.3×35.7×60 |
1201×1107×1525/ 47.3×43.6×60.0 |
1200×1228×1993/ 47.3×48.3×78.5 |
1201×1498 ×1993/ 47.3×59.0×78.5 |
1554×1872×1935/ 61.2×73.7×76.2 |
||
Net weight (kg / lbs) |
220±10 / 485±22 |
250±10 / 551±22 |
280±10 / 617±22 |
360±10 / 794±22 |
410±10 / 904±22 |
480±10 / 1058±22 |
||
Cable port |
Basically one hole provided / Ø 50mm (2”), Optionally max. two holes available / Ø 50 or 80mm (2 or 3.2”) |
|||||||
Interface port |
Basically RS-232C, [RS-485 : optional] |
|||||||
Electrical requirements | AC230V, 1ph, 60Hz | 11.8 A | 13.9 A | 13.9 A | 14.9 A | 14.9 A | 24A | |
Cat.No. | AAHC2005K | AAHC2015K | AAHC2025K | AAHC2035K | AAHC2045K | AAHC2055K | ||
AC230V, 1ph, 50/60Hz | 11.8 A | 13.9 A | 13.9 A | 14.9 A | 14.9 A | 24A | ||
Cat.No. | AAHC2005K | AAHC2015K | AAHC2025K | AAHC2035K | AAHC2045K | AAHC2055K |
1) All specifications are under ambient temperature 20℃ (68℉), No load.
2) Technical data according to DIN 12880, IEC 60068.
for Floor Standing Chambers
Accessory check list□ Standard ○ Optional
Description | Models | |||||
---|---|---|---|---|---|---|
TH-G | TH-I | TH-KH | TH-TG | TH-ICH | TH-CR | |
Recorder (6 points) | ○ | ○ | ○ | ○ | ○ | ○ |
Recorder (digital, 6 channels) | ○ | ○ | ○ | ○ | ○ | ○ |
interface converter RS-485C → 232C included a cable (5m / 16.4ft) | ○ | ○ | ○ | ○ | ○ | ○ |
Interface cable (5m / 16.4ft) | ○ | ○ | ○ | ○ | ○ | ○ |
Warning signal lamp | ○ | ○ | ○ | ○ | ○ | ○ |
Inner glass door | ○ | ○ | ○ | ○ | ○ | - |
Viewing window | □ | □ | □ | □ | - | □ |
Wire shelf | □ | □ | □ | □ | □ | □ |
Perforated shelf | ○ | ○ | ○ | ○ | ○ | ○ |
Cable port (Ø 50mm / 2”) | □ | □ | □ | □ | □ | □ |
Cable port (Ø 80mm / 3.2”) | ○ | ○ | ○ | ○ | ○ | ○ |
Temperature sensor (RTD type) | □ | □ | □ | □ | □ | □ |
Humidity sensor | □ | □ | □ | □ | □ | □ |
Fluorescent lamp (Cool White) | - | - | - | - | □ | - |
UVA lamp | - | - | - | - | □ | - |
UV sensor | - | - | - | - | □ | - |
Illumination Sensor | - | - | - | - | □ | - |
HEPA filter | - | - | - | - | - | □ |
ULPA filter | - | - | - | - | - | ○ |
Water cartridge tank (Water Container) | □ | □ | □ | □ | - | □ |
Water purifier | ○ | ○ | ○ | ○ | ○ | ○ |
Direct water system | ○ | ○ | ○ | ○ | ○ | ○ |
1) 80mm cable access hole is NOT available for 25L chamber.
Ordering information
Cat. No. | Description | Suitable for |
---|---|---|
AAA8T500 | Recorder (6 points) | All models |
AAA8T505 | Recorder (digital, 6 channels) | All models |
AAA8T540 | interface converter RS-485C → 232C included a cable (5m / 16.4ft) |
All models |
AAA8T542 | Interface cable (5m / 16.4ft) | All models |
AAA80550 | Warning signal lamp | All models |
AAA81552 | Inner glass door | TH-G/I/KH-180 |
AAA81551 | TH-G/I/KH-300, 408, CR-270 | |
AAA81550 | TH-G-800, 1000 | |
AAAC2501 | TH-TG-180 | |
AAAC2502 | TH-TG-300, 408 | |
AAAC2503 | TH-TG-800, 1000 | |
AAA81554 | TH-ICH-300 | |
AAA81555 | TH-ICH-800 | |
AAA8T610 | Cable port (Ø 50mm / 2”) | All models |
AAA8T611 | Cable port (Ø 80mm / 3.2”) | All models |
00CFA0001185 | Temperature sensor (RTD type) | TH-G/I/GUmodels |
00CFA0001923 | TH-TG/ICH/CRmodels | |
00CFA0007113 | Humidity sensor | All models |
00RTD0001190 | Fluorescent lamp (cool white) | TH-ICH-300 |
00RTD0001191 | TH-ICH-800 | |
00RTD0001188 | UVA lamp | TH-ICH-300 |
00RTD0001189 | TH-ICH-800 | |
AAA80680 | THE-680 UV sensor | TH-ICH-300/800 |
AAA80681 | THE-681 Illumination sensor | TH-ICH-300/800 |
AAA80661 | Door lock device | TH-ICH-300/800 |
EDA9184 | HEPA filter | TH-CR-270 |
00EDA0009175 | ULPA filter | TH-CR-270 |
AAA80622 | Water cartridge tank | All models |
Cat. No. | Description | Suitable for |
---|---|---|
AAA8T625 | Water purifier | All models |
AAA80620 | Direct water system | All models |
00EDA0008212 | Wire shelf | TH-G/I/KH-180 |
00EDA0008213 | TH-G/I/KH-300 | |
00EDA0008214 | TH-G/I/KH-408 | |
00EDA0008215 | TH-G-800 | |
00EDA0008216 | TH-G-1000 | |
00RTD0001302 | TH-TG-180 | |
00RTD0001303 | TH-TG-300 | |
00RTD0001300 | TH-TG-408 | |
00RTD0001304 | TH-TG-800 | |
00RTD0001301 | TH-TG-1000 | |
00RTD0001305 | TH-G/TG-1500 | |
00RTD0001196 | TH-ICH-300 | |
00RTD0001198 | TH-ICH-800 | |
00STT0001040 | TH-CR-270 | |
AAA80602-1 | Perforated shelf | TH-G/I/KH-180 |
AAA80602-2 | TH-G/I/KH-300 | |
AAA80602-3 | TH-G/I/KH-408 | |
AAA80602-4 | TH-G-800 | |
AAA80602-5 | TH-G-1000 | |
AAA80604-11 | TH-TG-180 | |
AAA80604-12 | TH-TG-300 | |
AAA80604-13 | TH-TG-408 | |
AAA80604-14 | TH-TG-800 | |
AAA80604-15 | TH-TG-1000 | |
AAA80604-16 | TH-G/TG-1500 | |
AAA80604-2 | TH-ICH-300 | |
AAA80604-4 | TH-ICH-800 | |
AAA80603-1 | TH-CR-270 |
Inquiry Form